{"id":1927,"date":"2017-04-02T17:05:37","date_gmt":"2017-04-02T14:05:37","guid":{"rendered":"https:\/\/akronex.com\/?page_id=1927"},"modified":"2022-10-10T20:08:41","modified_gmt":"2022-10-10T17:08:41","slug":"karbondioksit-gazli-sondurme-sistemleri","status":"publish","type":"page","link":"https:\/\/akronex.com.tr\/en\/karbondioksit-gazli-sondurme-sistemleri\/","title":{"rendered":"AKRONEX CO2 Fire Suppression Systems"},"content":{"rendered":"<p>[vc_row bg_parallax=&#8221;off&#8221; css=&#8221;.vc_custom_1491042551602{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 20px !important;padding-bottom: 0px !important;}&#8221;][vc_column][vc_column_text css=&#8221;.vc_custom_1522004568862{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}&#8221;]<\/p>\n<h2>Carbon dioxide gas extinguishing systems<\/h2>\n<p>[\/vc_column_text][vc_separator css=&#8221;.vc_custom_1491042509489{margin-top: 0px !important;margin-bottom: 20px !important;padding-top: 10px !important;padding-bottom: 10px !important;}&#8221;][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;2654&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;2119&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;2653&#8243; img_size=&#8221;full&#8221;][vc_single_image image=&#8221;2658&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_btn title=&#8221;AKRONEX C02 Fire Suppression Systems Catalog&#8221; style=&#8221;flat&#8221; color=&#8221;primary&#8221; size=&#8221;lg&#8221; i_icon_fontawesome=&#8221;&#8221; add_icon=&#8221;true&#8221; link=&#8221;url:%2Fwp-content%2Fuploads%2F2022%2F10%2FAkronex-CO2-Interactive.pdf|title:AKRONEX%20C02%20Carbon%20Dioxide%20Fire%20Suppression%20Systems|target:_blank&#8221;][vc_column_text]<span style=\"font-weight: 400;\">Carbon dioxide is a colorless, scentless and non conductive gas that can effect quickly and efficiently into the protected area. Its density is about 50% higher than .?<\/span><span style=\"font-weight: 400;\">the air density. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">During extinguishing, it is seen as a white mist. It does not make residue on the materials or affect adversely the materials. <\/span><span style=\"font-weight: 400;\">Reduces the concentration of oxygen causes suppression to fire in the space and creates a cooling effect causedby rapid expansion of the gas. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Even if the CO<\/span><span style=\"font-weight: 400;\">2<\/span> <span style=\"font-weight: 400;\">concentration is low in concentration, it should not be ignored and considered to be a danger to breathing. Also, the visibility during discharge is greatly reduced due to the formation of CO<\/span><span style=\"font-weight: 400;\">2<\/span> <span style=\"font-weight: 400;\">mist. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">This fire suppression can be applied in areas such as transformer rooms where people are not always present when appropriate safety measures are provided. After completing the suppression system, the area must be adequately ventilated. Because the density of carbon dioxide gas is heavier than air, it accumulates at low.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">CO<\/span><span style=\"font-weight: 400;\">2 <\/span><span style=\"font-weight: 400;\">is stored in pressurized cylinders up to 60 bar at 21?C. The distribution system consists of a series of 67.5 liter cylinders, which are tested at 250 bar, charged using a filling factor of 0.75 Kg \/ L or 0.67 Kg \/ L, with maximum storage temperatures of 40 ?C and 50 ?C. <\/span><\/p>\n<h2><strong>Features and Advantages<\/strong><\/h2>\n<ul>\n<li><span style=\"font-weight: 400;\"> No ozone damage,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Physical extinguishing,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Used for local extinguishing purposes,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Not used in areas where human presence,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> The cost of refilling is low, widely available,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> The discharge time is 60 seconds, (30 seconds for local systems).<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> The minimum discharge time calculated according to the standards should be 60 seconds.<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> For local applications, the discharge time should be at least 30 seconds.<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> If longer cooling time is required to complete the extinguishing process, the discharge time can be increased.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Discharge Time<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\"> The minimum discharge time calculated according to the standards should be 60 seconds. <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> For local applications, the discharge time should be at least 30 seconds. <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> If longer cooling time is required to complete the extinguishing process, the discharge time can be extended.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>Usage Areas<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Several fire extinguishing applications where CO<\/span><span style=\"font-weight: 400;\">2<\/span><span style=\"font-weight: 400;\"> is?<\/span><span style=\"font-weight: 400;\">suitable are listed below.<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\"> WPP (Wind Power Plant), HEPP,(Hydroelectric Power?<\/span>Plants),<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-weight: 400;\"> SPP (Solar Power Plants) and GPP(Geothermal Power?<\/span>Plants),<\/li>\n<\/ul>\n<ul>\n<li><span style=\"font-weight: 400;\"> Electrical equipment (machines, transformers, etc.),<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Painting cabinets, industrial ovens, etc,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Electronic control units and data processing centers,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Closed storage areas, dust pipes, and tunnels etc,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Closed frame spinning machines,<\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Silos, archives, flammable liquid storage areas.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><strong>Cylinder Storage Containers<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">The cylinders of AKRONEX CO<\/span><span style=\"font-weight: 400;\">2<\/span> <span style=\"font-weight: 400;\">Fire Suppression System?s cylinders can be fixed and stored in the container according to the customer request. This solution provides ease of maintenance, transportation and installation. This creates a more secure environment.<\/span><\/p>\n<h3><strong>Akronex CO2 Weighing Devices<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Gas leakage in the cylinders can be measured by weighing the cylinders and using special test?<\/span><span style=\"font-weight: 400;\">devices. In order to continuously monitor the amount of gas in the cylinder in AKRONEX CO<\/span><span style=\"font-weight: 400;\">2?<\/span><span style=\"font-weight: 400;\">systems, the special design of AKRONEX Weighing System can be installed optionally.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><b>Weighing Device Features<\/b><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\"> Body &amp; Frame Made of Aluminium <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Flame Resistant Limit Switch <\/span><\/li>\n<li><span style=\"font-weight: 400;\"> Rust Free<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">People who benefit more from nature and world blessings by the development of technology have also caused to occur?<\/span><span style=\"font-weight: 400;\">pollution at the same time. Carbon dioxide fire protection systems are?<\/span><span style=\"font-weight: 400;\">a responsible choice to protect nature.<\/span>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>","protected":false},"excerpt":{"rendered":"<p>[vc_row bg_parallax=&#8221;off&#8221; css=&#8221;.vc_custom_1491042551602{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 20px !important;padding-bottom: 0px !important;}&#8221;][vc_column][vc_column_text css=&#8221;.vc_custom_1522004568862{margin-top: 0px !important;margin-bottom: 0px !important;padding-top: 0px !important;padding-bottom: 0px !important;}&#8221;] Carbon dioxide gas extinguishing systems [\/vc_column_text][vc_separator css=&#8221;.vc_custom_1491042509489{margin-top: 0px !important;margin-bottom: 20px [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/pages\/1927"}],"collection":[{"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/comments?post=1927"}],"version-history":[{"count":35,"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/pages\/1927\/revisions"}],"predecessor-version":[{"id":3592,"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/pages\/1927\/revisions\/3592"}],"wp:attachment":[{"href":"https:\/\/akronex.com.tr\/en\/wp-json\/wp\/v2\/media?parent=1927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}